Page MenuHomeSoftware Heritage
Paste P607

smartctl output
ActivePublic

Authored by zack on Mar 9 2020, 9:25 AM.
$ sudo smartctl -a /dev/nvme0
smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.4.0-4-amd64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: SAMSUNG MZVLB1T0HALR-000L7
Serial Number: S3TPNX0K904114
Firmware Version: 4L2QEXA7
PCI Vendor/Subsystem ID: 0x144d
IEEE OUI Identifier: 0x002538
Total NVM Capacity: 1.024.209.543.168 [1,02 TB]
Unallocated NVM Capacity: 0
Controller ID: 4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 1.024.209.543.168 [1,02 TB]
Namespace 1 Utilization: 413.643.579.392 [413 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 002538 8981bb71b5
Local Time is: Mon Mar 9 09:25:00 2020 CET
Firmware Updates (0x16): 3 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 81 Celsius
Critical Comp. Temp. Threshold: 82 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 7.02W - - 0 0 0 0 0 0
1 + 6.30W - - 1 1 1 1 0 0
2 + 3.50W - - 2 2 2 2 0 0
3 - 0.0760W - - 3 3 3 3 210 1200
4 - 0.0050W - - 4 4 4 4 2000 8000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
- NVM subsystem reliability has been degraded
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x04
Temperature: 31 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 0%
Data Units Read: 12.057.521 [6,17 TB]
Data Units Written: 14.826.079 [7,59 TB]
Host Read Commands: 138.460.404
Host Write Commands: 243.297.638
Controller Busy Time: 637
Power Cycles: 998
Power On Hours: 650
Unsafe Shutdowns: 56
Media and Data Integrity Errors: 1
Error Information Log Entries: 14
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 31 Celsius
Temperature Sensor 2: 33 Celsius
Error Information (NVMe Log 0x01, max 64 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS
0 14 3 0x021d 0x4502 0x000 43499560 1 -